Root-resistant torch-on cap sheet for planter boxes and green roofs. Class I to AS 4654.1, UV stable, can stay exposed.
FORZAFLEX RR is the FORZAFLEX cap sheet for waterproofing that sits under soil and plants. Anti-root additives are blended through the bitumen, and the micro-mineral face is fully UV stable, so one sheet does the planted and exposed zones of a roof. CLASS I to AS 4654.1-2012, NATA-accredited Report No. 589-1. 10 m x 1 m roll.
Where to use it
Why waterproofers buy it
Coverage
About 9.1 m² effective per 10 m² roll after 75 mm side and 150 mm end laps, about 11 rolls per 100 m². Planters are lap-heavy, so allow well over 10% extra. It weighs about 495 kg per 100 m², so check the structure.
Not for
Foot or vehicle traffic (0.539 mm abrasion against a 0.2 mm limit, maintenance access only). Never put soil, ballast or plants straight on it: protection board, drainage cell, filter fabric and falls are required. Root resistance is not classified under an Australian Standard, so check with Forspec if a spec needs a certified test. Hot work permit and fire watch required.
Pickup available at The Waterproofing Shop
Usually ready in 24 hours

FORZAFLEX RR Torch-On Sheet Membrane 1m x 10m
The Waterproofing Shop
22/872 Canterbury Road
Roselands NSW 2196
Australia

Correct application makes all the difference.
NOT A TRAFFICABLE MEMBRANE. Certified abrasion depth is 0.539 mm against a 0.2 mm pedestrian limit, so the membrane is suitable for MAINTENANCE ACCESS ONLY; where pedestrian or vehicle traffic is required, design a separate trafficable wearing surface over the membrane. Root resistance protects the membrane; it does not substitute for a correctly designed planted build-up, and protection board, drainage cell, filter fabric and drainage falls must all be provided. Root resistance is not classified under an Australian Standard - where a project specification requires certified root resistance to a nominated test method, confirm the current position with FORSPEC Technical Services. Never place growing medium, soil, ballast or planting directly on the membrane; a protection layer is mandatory. Classified CLASS I, low extensibility; where the design requires a Class II or Class III membrane for movement accommodation, specify a higher-class FORSPEC membrane. Torch application direct to combustible substrates is PROHIBITED; a non-combustible overlay board must be installed first. Torch-applied work is hot work and must not proceed without a hot work permit, a fire watch and the fire safety measures in the TDS. Do not torch onto wet, damp, green or uncured substrates, or onto wet or uncured primer. Do not overheat; excessive heat degrades the bitumen, damages the polyester reinforcement and may impair the anti-root additive system. No cold joints, fish-mouths or open seams are permitted at any lap - a lap that has not fused is the pathway a root will find. Not compatible in direct contact with polystyrene insulation, PVC membranes or plasticised sheet materials without an approved separation layer. Bitumen fume is classified as a suspected carcinogen.
| Membrane Classification | CLASS I, low extensibility (AS 4654.1-2012, Report 589-1, NATA accredited to ISO/IEC 17025) |
| Product Type | Root-resistant APP-modified bitumen torch-applied mineral cap sheet |
| Reinforcement | High-strength non-woven polyester composite |
| Upper Surface | Micro-mineral, UV stable |
| Lower Surface | Thermofusible polyethylene film |
| Root Resistance | Anti-root additive system - prevents root penetration and biological attack* |
| Nominal Thickness | 4.0 mm (EN 1849-1) |
| Roll Size | 10m x 1m (10m2 gross per roll) |
| Approximate Roll Weight | 45 kg |
| Rolls Per Pallet | 20 |
| Control Elongation at Break | 39% (AS 1145.3, Report 589-1) |
| Control Tensile Strength | 2.31 MPa (AS 1145.3, Report 589-1) |
| Elongation After Water Immersion 56 Days | 40% (Report 589-1) |
| Elongation After Detergent Immersion 56 Days | 34% (Report 589-1) |
| Elongation After Heat Ageing | 33% (Report 589-1) |
| Elongation After Ultraviolet Exposure | 36% (Report 589-1) |
| Cyclic Movement | Pass, 50 cycles completed, no rupture, crazing or tears (AS 4654.1 Appendix B, Report 589-1) |
| Abrasion, Non-Trafficable | 0.099 mm depth, CS-10 wheel, 500 cycles, limit 0.2 mm (AS 1580.403.2, Report 589-1) |
| Abrasion, Trafficable | 0.539 mm depth, H-22 wheel, 1000 cycles - does not meet the trafficable requirement, maintenance access only (AS 1580.403.2, Report 589-1) |
| Bond Strength to Unprimed Concrete | 21.72 N (ASTM C794, Report 589-1) |
| Field Seam Strength | 286.37 N/25 mm (AMTM005, Report 589-1) |
| Dimensional Stability | No changes observed over two full cycles (ASTM D6207, Report 589-1) |
| Water Vapour Transmission | 0.03 g/m2/24h (ASTM E96 desiccant method, Report 589-1) |
| Temperature Resistance | 0.09 g/m2/24h after cycling from -16.3C to 85C (AMTM004, Report 589-1) |
| Service Temperature Range | -15C to +85C |
| UV Exposure | Fully UV stable - may be left exposed (Report 589-1) |
| Application Method | Torch-applied heat welding by propane gas torch or approved torching equipment |
| Application Temperature | 5C to 40C ambient. Do not torch in rain, on wet substrates or in high wind* |
| Minimum Side Lap | 75 mm |
| Minimum End Lap | 150 mm |
| End Lap Stagger | Minimum 1 m between adjacent sheets |
| Minimum Upturn Height | 150 mm unless specified otherwise |
| Minimum Substrate Fall | 1:100, draining positively to outlets |
| Shelf Life | 24 months from manufacture, stored as specified* |
| Hazard Classification | Hazardous Chemical, Non-Dangerous Goods, signal word DANGER; Chemwatch 9024-62 |
| * Typical Forspec R&D characteristic values | |
Before
After
Gold Coast, QLD
Before
After
Sydney, NSW
Before
After
Perth, WA
Before
After
Melbourne, VIC
Brisbane, QLD
Step-by-step from prep to top coat. Filmed on the tools, not in a studio.

We supply premium waterproofing products backed by expert advice, fast service and real-world experience.
FORZAFLEX RR is a torch-on bituminous sheet membrane in 1m x 10m roll format. Standard torch-applied roofing membrane used for flat roofs, balconies, planter boxes, and below-ground tanking. Apply with a roofing torch (LPG).
Torch-on membranes are heated with an open flame to melt the bitumen back of the sheet, which then bonds permanently to the substrate and overlapping membrane. Higher adhesion than self-adhesive and faster on large areas, but requires hot work permits and trained applicators.
Roll out the membrane, light the torch, heat the back of the membrane and the substrate simultaneously, then roll the membrane into the molten bitumen. Lap overlaps 100-150mm and heat-weld the laps for sealed joints.
Flat roofs, balcony decks under tiles or pavers, planter boxes, and below-ground tanking where torch-applied is preferred over liquid or self-adhesive. Coverage is 10 m² per roll at 1m x 10m.
Torch-on application requires trained applicators with hot work permits per Australian workplace health and safety requirements. Get formal training before applying torch-on systems.