Pool System Build-Up
- 1 Concrete Substrate
- 2 Crack Repair (if required)
- 3 ACTFLEX FLEXPLUS
- 4 ACTFLEX HYDROPLUG
- 5 ACTFLEX AT MESH
- 6 ACTFLEX 988 CWP (2 Coats)
- 7 Tile Adhesive
- 8 Pool Finish
Flood Test Balloon
$28.00
ACTFLEX 400 CLEAR Waterproofing Membrane
$66.00
Innovative Tools 230mm FC Sheeting Puddle Flange Recess Kit
$504.00
Soudal T-Rex Crystal
$17.85
Puddle Pro 90mm Puddle Flange
$15.00
Puddle Pro 100mm Puddle Flange
$15.00
BAT Spike Roller 21mm x 500mm
$55.00
ACTFLEX 400 CLEAR Temporary Leak Repair Kit For Leaking Bathrooms & Balconies
$94.35

Reinforced PVC sheet membrane, Class II to AS 4654.1. Welded laps, no glue, and you can leave it exposed.
ACTFLEX POLYFIN Type P is a scrim-reinforced PVC sheet for roofs, podiums, tanks and below-ground work. It is mechanically fastened and hot-air welded at every lap, so there is no adhesive bond line to fail. Certified Class II to AS 4654.1-2012 in NATA-accredited testing (Report 608-1). 1.5 mm thick, 2 m x 20 m roll.
Where to use it
Why waterproofers buy it
Coverage
2 m x 20 m roll: 40 m² gross, 39.0 m² effective at a 50 mm side lap, 38.0 m² at 100 mm. Allow at least 10% extra on a simple rectangular roof, more on cut-up areas. Confirm the lap width in the project spec before ordering.
Not for
Direct contact with bitumen, asphalt, torch-on membranes, polystyrene insulation or solvent-based coatings and sealants without a separation layer, regular vehicle traffic, substrates that cannot hold the fasteners, falls under 1% (1:100), free water or green concrete, or potable water contact without written Forspec confirmation (no AS/NZS 4020 certification held).
Pickup available at The Waterproofing Shop
Usually ready in 24 hours

POLYFIN Type P 1.5mm x 2m x 20m (Reinforced)
The Waterproofing Shop
22/872 Canterbury Road
Roselands NSW 2196
Australia

Correct application makes all the difference.
Mechanical anchorage is the sole means of restraint, so substrates that cannot develop the required fastener pull-out capacity are not approved and fastener selection, fixing density and pattern must be designed by the project engineer for the wind uplift condition. Not compatible with bituminous products, polystyrene insulation or solvent-based coatings and sealants in direct contact, and a separation layer is mandatory where contact occurs. Certified for pedestrian and occasional service vehicle traffic only; regular vehicle traffic is NOT approved and needs a separate trafficable wearing surface. Substrate falls must be a minimum of 1% (1:100) with positive drainage, ponding is not a design condition. Do not lay over free water, ponded water, green or uncured concrete. Laps must be clean and dry at the moment of welding and every seam must be probe-tested. No AS/NZS 4020 certification is held, so potable-water contact requires written confirmation from FORSPEC Technical Services.
| Membrane Classification | CLASS II (medium extensibility), AS 4654.1 Report 608-1 |
| Product Type | TYPE P scrim-reinforced PVC field sheet |
| Chemical Base | Plasticised PVC |
| Installation Method | Mechanically fastened, semi-loose laid, hot-air welded laps |
| Roll Size | 2m x 20m (40 m2 gross per roll) |
| Thickness | 1.5mm and 2.0mm |
| Control Elongation at Break | 141% (AS 1145.3, Report 608-1) |
| Control Tensile Strength | 12.85 MPa (AS 1145.3, Report 608-1) |
| Elongation at Break after UV Exposure | 320% against a 57% pass requirement (Report 608-1) |
| Abrasion Resistance, Non-Trafficable | 0.016mm depth of abrasion, CS-10 wheel 500 cycles (AS 1580.403.2, Report 608-1) |
| Abrasion Resistance, Trafficable | 0.077mm depth of abrasion, H-22 wheel 1000 cycles (AS 1580.403.2, Report 608-1) |
| Field Seam Strength | 383.71 N/25mm (AMTM005, Report 608-1) |
| Puncture Resistance | 1000mm drop height without leakage, Method A (BS EN 12691, Report 608-1) |
| Dimensional Stability | No changes observed (ASTM D6207, Report 608-1) |
| Water Vapour Transmission | 0.65 g/m2/24 h (ASTM E96 desiccant method, Report 608-1) |
| Temperature Resistance | 0.52 g/m2/24 h after cycling from -17.8C to 85C (AMTM004, Report 608-1) |
| Low Temperature Flexibility | -25C, no cracking* |
| Root Penetration Resistance | Resistant, meets standard test criteria* |
| Fire Behaviour | Self-extinguishing PVC formulation, no Australian fire classification currently held* |
| Design Service Life (exposed system) | 20 years, indicative* |
| Minimum Substrate Fall | 1% (1:100), draining positively to outlets |
| Weld Temperature and Speed | Established by trial weld on the day, for the prevailing conditions |
| Storage | Rolls stored upright, on end, under cover |
| SDS Reference | Chemwatch 9041-05 (Type P) |
| * Typical Forspec R&D characteristic values | |
Before
After
Gold Coast, QLD
Before
After
Sydney, NSW
Before
After
Perth, WA
Before
After
Melbourne, VIC
Brisbane, QLD
Step-by-step from prep to top coat. Filmed on the tools, not in a studio.

We supply premium waterproofing products backed by expert advice, fast service and real-world experience.